Tech Topics: Jet Pump Control Valves – Part 2
by Bob Pelikan
May 1, 2007
This is the second part of our jet pump series.
Last month, we said that a jet pump was a centrifugal pump with a jet assembly
(also called an injector), either integrally attached, as in the case of
shallow-well jets, or remotely attached, as in the case of deep-well jets. We
further explained that a shallow-well jet pump pulls the water up to the
surface, and is limited by atmospheric pressure to a depth of about 25 feet.
Deep-well jets – with the jet assembly located down in the well below the water
level – push the water to the surface, and can pump from as deep as 200 feet.
The operation of a jet pump requires a certain amount of water to be circulated
back through the jet assembly as drive water. In a shallow-well jet pump, the
amount of water diverted is governed by the internal construction of the pump,
and is not adjustable because the narrow range of pumping conditions can be met
without having to adjust the amount of drive water. The performance of a deep-well jet pump, on
the other hand, can be optimized to specific pumping conditions through the use
of a control valve to create the right amount of backpressure, and this article
will explain their function and how to adjust them.
Types of Control Valves
Control valves can be as simple as a manually adjustable flow-restricting valve
built into or attached to the outlet port of the pump (see Figure 1). Or, they
can be as complex as a pilot or manually operated spring-loaded diaphragm
valve, like a pressure regulator, attached to the outlet port of the pump (see
Figure 2). Used manually, diaphragm valves operate just like any manually operated
valve to restrict the pump’s discharge to create backpressure to force drive
water to the jet. Their advantage over a simple gate or ball valve is that they
can be adjusted more precisely and hold their setting better. Manually adjusted
backpressure valves are set to a specific pumping level, and if the level
changes, the pump’s performance will be affected.
Some jet pump manufacturers offer an automatic backpressure valve that has a
small line connected to it from the suction side of the pump. Vacuum regulates
the valve and, thus, the output of the pump, to provide optimum performance as
the water level in the well goes up and down. When the water level is high, the
vacuum on the suction side is low and the valve is wide open. As the water level
drops, the vacuum increases, and the valve begins to close to circulate more
drive water down to the jet to provide the additional lift needed to pump from
a deeper level. Automatic backpressure valves are factory-set and need no field
adjustment.
How to Set Manual Control Valves
Before making the final adjustments, the pump must be primed and the system
purged of air. To do this, manually fill the pump and piping down to the jet
with water and turn on the pump with the control valve open. You should see
pressure at the outlet of the pump, indicating it is primed. Then, begin to
close the control valve to purge air from the rest of the
system.
Method one, using a pressure gauge – Some manufacturers recommend adjusting the
control valve to provide a specific amount of backpressure between the pump and
the control valve, usually 20 psi. To set it this way, run the pump until the
well has stabilized and the pumping level is established.
Once there, set the control valve to give you 20 psi on a gauge on the outlet
side of the pump before the valve.
Method two, using an amp meter – With the pump pumping at the stabilized
pumping level, use an amp probe to set the control valve to give you an amp
reading equal to the nameplate amps of the pump. Don’t use service-factor amps
because you could overload the motor if the pumping level rises in the
well.
Method three, using your ears – This is a little less orthodox, but one used by
many old-time jet pump installers. Open a faucet near the pump so there is no
backpressure from the tank, and so you can observe and estimate the discharge
flow rate. Slowly open the valve, until the flow rate appears to maximize. If
you continue to open the bypass, you will reach a point where the pump starts
to rattle – as if it is full of marbles – due to cavitation. If you continue to
open the valve beyond this point, the pump will lose prime, and you’ll have to
start over. Back off one turn on the backpressure-adjusting screw, and tighten
the lock nut. You’re done.
You can check your setting with a pressure gauge on the discharge and a bucket
to measure flow. Watching the pressure gauge, restrict the discharge flow until
the gauge reads 30 psi. Using the bucket and a stopwatch, measure the flow rate
at this pressure, and verify that it agrees with the manufacturer’s performance
tables for the pump/injector package you have. If not, play with the control
valve adjustment to maximize the flow.
Pumping from a Slow-producing Well
Since air entering a jet pump system causes it to stop pumping and necessitates
re-priming the system, it is important to take precautions to ensure the water
level in the well does not drop below the inlet of the foot valve. To prevent
air from entering the foot valve in a slow-producing well, try the following.
Because a pump cannot lift water more that 34 feet maximum due to the
limitations of atmospheric pressure, installing a 34-foot section of suction
pipe below the injector will preclude the possibility of the water level being
drawn down below the foot valve. As the well draws down, increasing the suction
head on the injector, its pumping capacity slows down until it matches that of
the well. With the foot valve set at 34 feet below the injector, even in a well
with no production, air cannot enter the foot valve because the injector is not
able to lift the last foot of water to empty the well.
Summing up, shallow-well jet pumps have the jet assembly built into or attached
to the suction port of the pump, and are designed to pull water out of a
shallow well (less than 25 feet in depth). Deep-well jet pumps have the jet
assembly down in the well so they can push the water up out of the well, and
they are not confined by the 25-foot limit. They can pump water from as deep as
200 feet. Convertible jet pumps are designed with the injector assembly
removable and small enough to fit into 4-inch and larger well casing. They can
be used either as a shallow-well jet pump with the injector assembly attached
to the pump, or as a deep-well jet pump, with the injector assembly down in the
well. But they cannot pump from as deep as a dedicated deep-well jet – 130 feet
is about as deep as they go.
Properly sized, installed and adjusted, a jet pump can be a real workhorse and
provide years of trouble-free service. Millions of people around the world
depend on jets for their water. Hopefully, this series has given you a better
understanding of the inner workings of these thoroughbreds.
Next month, we learn how to determine the pressure and flow requirements of a
pumped water system. ’Til then …. ND
|